Reference Guide
Step Task Command Command Mode
Default: None.
5
Congure the priority used by a server CNA to select the
FCF for a fabric login (FLOGI). Range: 1–255. Default: 128.
fcf-priority priority
FCoE MAP
6
Enable the monitoring FIP keepalive messages (if it is
disabled) to detect if other FCoE devices are reachable.
Default: FIP keepalive monitoring is enabled.
keepalive
FCoE MAP
7
Congure the time interval (in seconds) used to transmit
FIP keepalive advertisements.
Range: 8–90 seconds. Default: 8 seconds.
fka-adv-period seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on a server-facing port or
port channel:
• The port is congured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
• The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by performing FLOGIs on upstream
virtualized FCF ports. The NPG forwards the FLOGIs as FDISC messages to a SAN switch.
Step
Task Command Command Mode
1
Congure a server-facing Ethernet port or port channel
with an FCoE map.
interface
{tengigabitEthernet slot/
port | port-channel num}
CONFIGURATION
2
Apply the FCoE/FC conguration in an FCoE map on the
Ethernet port. Repeat this step to apply an FCoE map to
more than one port, for example:
Dell# interface tengigabitEthernet 0/0
Dell(config-if-te-0/0)#
fcoe-map
SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map SAN_DCB1
Dell(config-if-po-3)# fcoe-map
SAN_FABRIC_A
Dell# interface fortygigabitEthernet
0/48
Dell(config-if-fo-0/0)# fcoe-map
SAN_FABRIC_A
fcoe-map map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using the map
settings.
no shutdown
INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are congured by default to operate in N port mode to connect to an F port on an FC switch in a
fabric. You can apply only one FCoE map on an FC port.
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric, whose settings in the FCoE
map are congured on the port and exported to downstream server CNA ports.
NPIV Proxy Gateway