Reference Guide

Step Task Command Command Mode
Default: None.
5
Congure the priority used by a server CNA to select the
FCF for a fabric login (FLOGI). Range: 1–255. Default: 128.
fcf-priority priority
FCoE MAP
6
Enable the monitoring FIP keepalive messages (if it is
disabled) to detect if other FCoE devices are reachable.
Default: FIP keepalive monitoring is enabled.
keepalive
FCoE MAP
7
Congure the time interval (in seconds) used to transmit
FIP keepalive advertisements.
Range: 8–90 seconds. Default: 8 seconds.
fka-adv-period seconds
FCoE MAP
Applying an FCoE Map on Server-facing Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on a server-facing port or
port channel:
The port is congured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by performing FLOGIs on upstream
virtualized FCF ports. The NPG forwards the FLOGIs as FDISC messages to a SAN switch.
Step
Task Command Command Mode
1
Congure a server-facing Ethernet port or port channel
with an FCoE map.
interface
{tengigabitEthernet slot/
port | port-channel num}
CONFIGURATION
2
Apply the FCoE/FC conguration in an FCoE map on the
Ethernet port. Repeat this step to apply an FCoE map to
more than one port, for example:
Dell# interface tengigabitEthernet 0/0
Dell(config-if-te-0/0)#
fcoe-map
SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map SAN_DCB1
Dell(config-if-po-3)# fcoe-map
SAN_FABRIC_A
Dell# interface fortygigabitEthernet
0/48
Dell(config-if-fo-0/0)# fcoe-map
SAN_FABRIC_A
fcoe-map map-name
INTERFACE or
INTERFACE
PORT_CHANNEL
3
Enable the port for FCoE transmission using the map
settings.
no shutdown
INTERFACE
Applying an FCoE Map on Fabric-facing FC Ports
The Aggregator, with the FC ports, are congured by default to operate in N port mode to connect to an F port on an FC switch in a
fabric. You can apply only one FCoE map on an FC port.
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric, whose settings in the FCoE
map are congured on the port and exported to downstream server CNA ports.
NPIV Proxy Gateway
221