Reference Guide
Adding a Stack Unit
You can add a new unit to an existing stack both when the unit has no stacking ports (stack groups) congured and when the unit
already has stacking ports congured. If the units to be added to the stack have been previously used, they are assigned the smallest
available unit ID in the stack.
To add a standalone Aggregator to a stack, follow these steps:
1. Power on the switch.
2. Attach SFP+ or direct attach cables to connect 10G ports on the switch to one or more switches in the stack.
3. Log on to the CLI and enter global conguration mode.
Login: username
Password: *****
Dell> enable
Dell# congure
4. Congure the Aggregator to operate in stacking mode.
CONFIGURATION mode
stack-unit 0 iom-mode
stack
5. Reload the switch. Dell Operating System automatically assigns a number to the new unit and adds it as member switch in the
stack. The new unit synchronizes its running and startup congurations with the stack.
EXEC Privilege mode
reload
If an Aggregator is already congured to operate in stacking mode, simply attach SFP+ or direct attach cables to connect 10G ports
on the base module of each stacked Aggregator. The new unit synchronizes its running and startup congurations with the stack.
Dell Networking OS Behavior: When you add a new Aggregator to a stack:
• If the new unit has been congured with a stack number that is already assigned to a stack member, the stack avoids a
numbering conict by assigning the new switch the rst available stack number.
• If the stack has been provisioned for the stack number that is assigned to the new unit, the pre-congured provisioning must
match the switch type. If there is a conict between the provisioned switch type and the new unit, a mismatch error message is
displayed.
Resetting a Unit on a Stack
Use the following reset command to reload any of the member units or the standby in a stack. If you try to reset the stack master,
the following error message is displayed:
% Error: Reset of master unit is not allowed.
To reset a unit on a stack, use the following command:
• Reset any designated stack member, except the management unit.
EXEC Privilege mode
reset stack-unitunit-number {hard}
• Hard reset any stack unit including master unit.
EXEC Privilege mode
power-cycle stack-unit [unit-number]
180