Reference Guide
0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts
0 Multicasts, 0 Broadcasts, 0 Unicasts
0 throttles, 0 discarded, 0 collisions, 0 wreddrops
Rate info (interval 299 seconds):
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 00:58:08
TenGigabitEthernet 0/2 is up, line protocol is down(error-disabled[UFD])
Hardware is DellForce10Eth, address is 00:1e:c9:f1:00:99
Current address is 00:1e:c9:f1:00:99
Server Port AdminState is N/A
Pluggable media not present
Interface index is 34411265
Internet address is not set
Mode of IP Address Assignment : NONE
DHCP Client-ID :tenG131001ec9f10099
--More--
show system
Displays the current status of all stack members or a specic stack member.
Syntax
show system [brief | stack-unit unit-id]
Parameters
brief (OPTIONAL) Enter the keywordbrief to view an abbreviated list of system information.
stack unit unit–id (OPTIONAL) Enter the keywordsstack unit then the stack member ID for information
on the stack member. The range is from 0 to 5.
Command Modes
• EXEC
• EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (show
system brief
command)
Dell#show system brief
Stack MAC : 00:01:e8:00:ab:03
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
--------------------------------------------------------------------------------
----
0 Member not present
1 Management online I/O-Aggregator I/O-Aggregator 8-3-17-38 56
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Dell#
Example (stack-unit
command)
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
70