Reference Guide
Usage Information
Use the show fcoe-map command to display the FC and FCoE parameters used to congure server-
facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on an FN 2210S Aggregator with the
FC Flex IO module NPIV proxy gateway.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC
storage trac is sent, and the FCoE VLAN to be used must be unique.
The following table describes the show fcoe-map brief output shown in the example below.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage trac between servers
and a fabric over the NPIV proxy gateway. The congured VLAN ID must be the
same as the fabric ID.
FC-MAP FCoE MAC address-prex value - The unique 24-bit MAC address prex that
identies a fabric.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are
valid: Active (all mandatory FCoE and FC parameters are correctly congured) or
Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly
congured).
Oper-State Operational status of link to the fabric: Up (link is up and transmitting FC trac),
Down (link is down and not transmitting FC trac), Link-wait (link is up and waiting
for FLOGI to complete on peer FC port), or Removed (port has been shut down).
The following table describes the show fcoe-map map-name output shown in the example below.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage trac between servers
and a fabric over the NPIV proxy gateway. The congured VLAN ID must be the
same as the fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. (This setting is not user-congurable.)
FC-MAP FCoE MAC address-prex value - The unique 24-bit MAC address prex that
identies a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are
valid: Active (all mandatory FCoE and FC parameters are correctly congured) or
Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly
congured).
245