Reference Guide

Command History
Version Description
9.6(0.0) Supported on the FN 2210S Aggregator.
9.3(0.0) Supported on the M I/O Aggregator.
Usage Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id vlan command.
Create a VLAN and then specify the congured VLAN ID in the fabric-id vlan command. Otherwise,
the following error message is displayed.
Dell(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does not exist
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
fcf-priority
In an FCoE map, congure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
Syntax
fcf—priority priority
Parameters
priority Enter the priority assigned to the FN 2210S Aggregator NPIV proxy gateway, which
appears to a downstream server CNA as an FCF. The range of FCF priority values
is from 1 to 255.
Defaults 128
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Command History
Version Description
9.6(0.0) Supported on the FN 2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex
IO module.
Usage Information
The FCF priority you assign to an FN 2210S Aggregator is used by server CNAs to select an upstream FCF
to use for a fabric login (FLOGI).
To remove a congured FCF priority from an FCoE map, enter the no fcf-priority command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between
servers and a SAN fabric.
240