Reference Guide

slot/port Enter the slot/port number.
Command Modes INTERFACE
Supported Modes All Modes
Command History
Version Description
9.4(0.0) Supported on the FN I/O aggregator. This command is supported in
Programmable-Mux (PMUX) mode only.
9.2(0.0) Introduced on the M I/O Aggregator.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example (Summary)
Dell#show interfaces te 0/3 pfc statistics
Interface TenGigabitEthernet 0/3
Priority Rx XOFF Frames Rx Total Frames Tx Total Frames
--------------------------------------------------------
0 0 0 0
1 0 0 0
2 0 0 0
3 0 0 0
4 0 0 0
5 0 0 0
6 0 0 0
7 0 0 0
show qos dcb-map
Display the DCB parameters congured in a specied DCB map.
Syntax
show qos dcb-map map-name
Parameters
map-name Displays the PFC and ETS parameters congured in the specied map.
Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.6(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Introduced on the M I/O Aggregator.
Usage Information
Use the show qos dcb-map command to display the enhanced transmission selection (ETS) and priority-
based ow control (PFC) parameters used to congure server-facing Ethernet ports.
The following table describes the show qos dcb-map output shown in the example below.
118