User`s guide

About PERC 6 and CERC 6/i Controllers 39
3
Patrol Read
adjusts the amount of controller resources dedicated to
Patrol Read
operations based on outstanding disk I/O. For example, if the
system is busy processing I/O operation, then
Patrol Read
uses fewer
resources to allow the I/O to take a higher priority.
4
Patrol Read
does not run on any disks involved in any of the following
operations:
Rebuild
Replace Member
Full or Background Initialization
Consistency Check
RAID Level Migration or Online Capacity Expansion
Patrol Read Modes
The following describes each of the modes Patrol Read can be set to:
Auto
(default)
— Patrol Read
is set to the
Auto
mode by default. In this
mode,
Patrol Read
is enabled to run automatically and start every seven
days on SAS and SATA HDDs.
Patrol Read
is not necessary on SSD and is
disabled by default. You can start and stop
Patrol Read
as well.
Manual
— Patrol Read
does not run automatically and you must start it
manually.
Disabled
— Patrol Read
is not allowed to start on the controller.