Personal Computer User Manual
Table Of Contents
- Hardware Owner’s Manual
- Contents
- About Your System
- Using the System Setup Program
- Installing System Components
- Recommended Tools
- Inside the System
- Removing and Replacing the Optional Front Bezel
- Opening and Closing the System
- Cooling Fans
- Cooling Shrouds
- Power Supplies
- Expansion Cards
- RAC Card
- System Memory
- Processors
- Processor VRMs
- Installing a Diskette Drive
- Installing an Optical Drive
- Hard Drives
- SAS Controller Cards
- Connecting an External SAS Tape Drive
- Connecting an External Fibre Channel Storage Device
- System Battery
- Control Panel Assembly (Service-Only Procedure)
- Fan Interposer Board (Service-Only Procedure)
- Power Distribution Board (Service-Only Procedure)
- Chassis Intrusion Switch (Service-Only Procedure)
- SAS Backplane (Service-Only Procedure)
- System Board (Service-Only Procedure)
- Troubleshooting Your System
- Safety First-For You and Your System
- Start-Up Routine
- Checking Basic Power Problems
- Checking the Equipment
- Troubleshooting Serial I/O Problems
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supplies
- Troubleshooting System Cooling Problems
- Troubleshooting System Memory
- Troubleshooting a Diskette Drive
- Troubleshooting an Optical Drive
- Troubleshooting a Hard Drive
- Troubleshooting a SAS Controller or SAS RAID Controller
- Troubleshooting an External SAS Tape Drive
- Troubleshooting Expansion Cards
- Troubleshooting the Microprocessors
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Glossary
- Index

Installing System Components 53
Figure 3-7. Expansion Slots
Installing an Expansion Card
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. See your Product Information Guide for complete information about safety
precautions, working inside the computer, and protecting against electrostatic discharge.
1
Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2
Turn off the system, including any attached peripherals, and disconnect the system from the electrical
outlet.
SLOT 5
SLOT 7
SLOT 6
SLOT 2
SLOT 4 SLOT 3
SLOT 1
INTERNAL_
STORAGE
RAC_CONN
back of system
front of system
Table 3-1. Expansion Slots
Slot Description
SLOT 1 x4 lane-width PCIe
SLOT 2 x4 lane-width PCIe
SLOT 3 x8 lane-width PCIe
SLOT 4 x8 lane-width PCIe
SLOT 5 x4 lane-width PCIe
SLOT 6 x4 lane-width PCIe
SLOT 7 x4 lane-width PCIe
INTERNAL_STORAGE reserved for controller cards
RAC_CONN reserved for RAC card