Personal Computer User Manual
Table Of Contents
- Hardware Owner’s Manual
- Contents
- About Your System
- Using the System Setup Program
- Installing System Components
- Recommended Tools
- Inside the System
- Removing and Replacing the Optional Front Bezel
- Opening and Closing the System
- Cooling Fans
- Cooling Shrouds
- Power Supplies
- Expansion Cards
- RAC Card
- System Memory
- Processors
- Processor VRMs
- Installing a Diskette Drive
- Installing an Optical Drive
- Hard Drives
- SAS Controller Cards
- Connecting an External SAS Tape Drive
- Connecting an External Fibre Channel Storage Device
- System Battery
- Control Panel Assembly (Service-Only Procedure)
- Fan Interposer Board (Service-Only Procedure)
- Power Distribution Board (Service-Only Procedure)
- Chassis Intrusion Switch (Service-Only Procedure)
- SAS Backplane (Service-Only Procedure)
- System Board (Service-Only Procedure)
- Troubleshooting Your System
- Safety First-For You and Your System
- Start-Up Routine
- Checking Basic Power Problems
- Checking the Equipment
- Troubleshooting Serial I/O Problems
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supplies
- Troubleshooting System Cooling Problems
- Troubleshooting System Memory
- Troubleshooting a Diskette Drive
- Troubleshooting an Optical Drive
- Troubleshooting a Hard Drive
- Troubleshooting a SAS Controller or SAS RAID Controller
- Troubleshooting an External SAS Tape Drive
- Troubleshooting Expansion Cards
- Troubleshooting the Microprocessors
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Glossary
- Index

30 About Your System
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system
continues a task. For example, before you format a diskette, a message will warn you that you may lose all
data on the diskette. Warning messages usually interrupt the task and require you to respond by typing
y
(yes) or
n (no).
NOTE: Warning messages are generated by either the application or the operating system. For more information,
see the documentation that accompanied the operating system or application.
Diagnostics Messages
When you run system diagnostics, an error message may result. Diagnostic error messages are not
covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help" on
page 129, and then follow the instructions in that section for obtaining technical assistance.
Alert Messages
Systems management software generates alert messages for your system. Alert messages include
information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For
more information, see the systems management software documentation.
Write fault
Write fault on selected
drive
Faulty diskette, optical/diskette drive
assembly, hard drive, or hard-drive
subsystem.
See "Troubleshooting a Diskette Drive"
on page 108, "Troubleshooting an
Optical Drive" on page 109, or
"Troubleshooting a Hard Drive" on
page 110.
NOTE: For the full name of an abbreviation or acronym used in this table, see "Glossary" on page 155.
Table 1-8. System Messages (continued)
Message Causes Corrective Actions