Personal Computer User Manual
Table Of Contents
- Hardware Owner’s Manual
- Contents
- About Your System
- Using the System Setup Program
- Installing System Components
- Recommended Tools
- Inside the System
- Removing and Replacing the Optional Front Bezel
- Opening and Closing the System
- Cooling Fans
- Cooling Shrouds
- Power Supplies
- Expansion Cards
- RAC Card
- System Memory
- Processors
- Processor VRMs
- Installing a Diskette Drive
- Installing an Optical Drive
- Hard Drives
- SAS Controller Cards
- Connecting an External SAS Tape Drive
- Connecting an External Fibre Channel Storage Device
- System Battery
- Control Panel Assembly (Service-Only Procedure)
- Fan Interposer Board (Service-Only Procedure)
- Power Distribution Board (Service-Only Procedure)
- Chassis Intrusion Switch (Service-Only Procedure)
- SAS Backplane (Service-Only Procedure)
- System Board (Service-Only Procedure)
- Troubleshooting Your System
- Safety First-For You and Your System
- Start-Up Routine
- Checking Basic Power Problems
- Checking the Equipment
- Troubleshooting Serial I/O Problems
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supplies
- Troubleshooting System Cooling Problems
- Troubleshooting System Memory
- Troubleshooting a Diskette Drive
- Troubleshooting an Optical Drive
- Troubleshooting a Hard Drive
- Troubleshooting a SAS Controller or SAS RAID Controller
- Troubleshooting an External SAS Tape Drive
- Troubleshooting Expansion Cards
- Troubleshooting the Microprocessors
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Glossary
- Index

About Your System 13
Hard-Drive Indicator Codes
The hard-drive carriers have two indicators—a drive-activity indicator and a drive-status indicator. See
Figure 1-2.
Figure 1-2. Hard-Drive Indicators
Table 1-3 lists the drive indicator patterns for RAID hard drives. Different patterns are displayed as drive
events occur in the system. For example, if a hard drive fails, the "drive failed" pattern appears. After the
drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive
ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for
operation" pattern appears, followed by the "drive online" pattern.
1 drive-status indicator (green
and amber)
2 green drive-activity indicator
Table 1-3. Hard-Drive Indicator Patterns for RAID
Condition Drive-Status Indicator Pattern
Identify drive/preparing for
removal
Blinks green two times per second
Drive ready for insertion or
removal
Off
NOTE: The drive status indicator remains off until all hard drives are
initialized after system power is applied. Drives are not ready for
insertion or removal during this time.
Drive predicted failure Blinks green, amber, and off.
Drive failed Blinks amber four times per second.
Drive rebuilding Blinks green slowly.
Drive online Steady green.
Rebuild halted Blinks green three seconds, amber three seconds, and off six seconds.
1