Server Hardware Owner's Manual
Table Of Contents
- About Your System
- Accessing System Features During Startup
- Front-Panel Features and Indicators
- LCD Panel Features (Optional)
- Hard-Drive Status Indicators
- Back-Panel Features and Indicators
- Guidelines for Connecting External Devices
- NIC Indicator Codes
- Power Indicator Codes
- Diagnostic Lights (Optional)
- LCD Status Messages (Optional)
- System Messages
- Warning Messages
- Diagnostics Messages
- Alert Messages
- Using the System Setup Program and UEFI Boot Manager
- Installing System Components
- Recommended Tools
- Inside the System
- Front Bezel (Optional)
- Opening and Closing the System
- Optical Drive (Optional)
- Hard Drives
- Removing a Drive Blank
- Installing a Drive Blank
- Removing a Hard-Drive Carrier
- Installing a Hard-Drive Carrier
- Removing a Hard Drive From a Hard-Drive Carrier
- Installing a Hard Drive Into a Hard-Drive Carrier
- Removing a Cabled Hard Drive
- Installing a Cabled Hard Drive
- Removing a Hard Drive From a Hard-Drive Bracket
- Installing a Hard Drive Into a Hard-Drive Bracket
- Expansion Card
- Expansion-Card Riser
- Internal USB Memory Key
- Cooling Shroud
- Integrated Storage Controller Card
- System Memory
- Cooling Fans
- iDRAC6 Express Card (Optional)
- iDRAC6 Enterprise Card (Optional)
- VFlash Media (Optional)
- Processor
- Power Supplies
- System Battery
- Control Panel Assembly
- SAS Backplane
- Power Distribution Board
- System Board
- Troubleshooting Your System
- Safety First-For You and Your System
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting the Video Subsystem
- Troubleshooting a USB Device
- Troubleshooting a Serial I/O Device
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supply
- Troubleshooting System Cooling Problems
- Troubleshooting a Fan
- Troubleshooting System Memory
- Troubleshooting an Internal USB Key
- Troubleshooting an Optical Drive
- Troubleshooting a Tape Backup Unit
- Troubleshooting a Hard Drive
- Troubleshooting an Expansion Card
- Troubleshooting the Processor
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Index

36 About Your System
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory
single-bit error (SBE)
logging and will not log
anymore SBEs until the
system is rebooted. “##”
represents the memory
module implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 153.
I1910 Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1911 LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912 SEL full.
Review & clear
log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
on the events, then clear
the SEL.
I1920 iDRAC6 Upgrade
Successful.
optional iDRAC6 has
been upgraded
successfully.
Information only.
W1228 RAID
Controller
battery
capacity <
24hr.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
Allow RAID battery to
charge to greater than
24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Getting Help" on
page 169.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
R310HOM.book Page 36 Thursday, March 4, 2010 1:03 AM