Server Hardware Owner's Manual
Table Of Contents
- About Your System
- Accessing System Features During Startup
- Front-Panel Features and Indicators
- LCD Panel Features (Optional)
- Hard-Drive Status Indicators
- Back-Panel Features and Indicators
- Guidelines for Connecting External Devices
- NIC Indicator Codes
- Power Indicator Codes
- Diagnostic Lights (Optional)
- LCD Status Messages (Optional)
- System Messages
- Warning Messages
- Diagnostics Messages
- Alert Messages
- Using the System Setup Program and UEFI Boot Manager
- Installing System Components
- Recommended Tools
- Inside the System
- Front Bezel (Optional)
- Opening and Closing the System
- Optical Drive (Optional)
- Hard Drives
- Removing a Drive Blank
- Installing a Drive Blank
- Removing a Hard-Drive Carrier
- Installing a Hard-Drive Carrier
- Removing a Hard Drive From a Hard-Drive Carrier
- Installing a Hard Drive Into a Hard-Drive Carrier
- Removing a Cabled Hard Drive
- Installing a Cabled Hard Drive
- Removing a Hard Drive From a Hard-Drive Bracket
- Installing a Hard Drive Into a Hard-Drive Bracket
- Expansion Card
- Expansion-Card Riser
- Internal USB Memory Key
- Cooling Shroud
- Integrated Storage Controller Card
- System Memory
- Cooling Fans
- iDRAC6 Express Card (Optional)
- iDRAC6 Enterprise Card (Optional)
- VFlash Media (Optional)
- Processor
- Power Supplies
- System Battery
- Control Panel Assembly
- SAS Backplane
- Power Distribution Board
- System Board
- Troubleshooting Your System
- Safety First-For You and Your System
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting the Video Subsystem
- Troubleshooting a USB Device
- Troubleshooting a Serial I/O Device
- Troubleshooting a NIC
- Troubleshooting a Wet System
- Troubleshooting a Damaged System
- Troubleshooting the System Battery
- Troubleshooting Power Supply
- Troubleshooting System Cooling Problems
- Troubleshooting a Fan
- Troubleshooting System Memory
- Troubleshooting an Internal USB Key
- Troubleshooting an Optical Drive
- Troubleshooting a Tape Backup Unit
- Troubleshooting a Hard Drive
- Troubleshooting an Expansion Card
- Troubleshooting the Processor
- Running the System Diagnostics
- Jumpers and Connectors
- Getting Help
- Index

About Your System 27
E122A CPU # VTT
Regulator
failure.
Reseat CPU.
Specified processor VTT
voltage regulator has
failed.
Reseat the processor. See
"Troubleshooting the
Processor" on page 160.
If the problem persists,
see "Getting Help" on
page 169.
E122C CPU Power
Fault. Power
cycle AC.
A power fault was
detected when powering
up the processor.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E122D Memory
Regulator #
Failed. Reseat
DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 153.
E122E On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E1310 Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside of the intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 151.
E1311 Fan module ##
RPM exceeding
range. Check
fan.
RPM of specified fan in
specified module is
outside of intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 151.
E1313 Fan redundancy
lost. Check
fans.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 152.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
R310HOM.book Page 27 Thursday, March 4, 2010 1:03 AM