NOTE: You need to enable SEKM on iDRAC before enabling SEKM on the PERC controller.
Storage.Controller.ControllerRekey (Read or Write)
Description
This pseudo attribute represents whether a rekey operation needs to be performed on the RAID
controller. Configurable via Server Configuration Profile (SCP) feature only.
Legal Values
True
False
Default Value FALSE
Write Privilege None
License Required iDRAC Basic, iDRAC Express, or iDRAC Enterprise
Dependency None
Storage.Controller.CopybackMode (Read or Write)
Description
This attribute represents the mode of restoring configuration of a virtual disk when a failed physical disk is
replaced in an array.
Legal Values
On
On with SMART
Off
Default Value On
Write Privilege Server Configuration
License Required iDRAC Basic, iDRAC Express, or iDRAC Enterprise
Dependency None
Storage.Controller.CurrentControllerMode (Read Only)
Description
This indicates controllers current personaility mode , which could be RAID or Non-RAID. PERC9 supports
RAID and HBA.Starting PERC 10, modes supported are RAID and Enhanced HBA
Legal Values
RAID
HBA
Enhanced HBA
NOTE: HBA or Enhanced HBA support is dependent on the type of PERC controller.
Default Value RAID
Write Privilege None
License Required iDRAC Basic, iDRAC Express, or iDRAC Enterprise
Dependency Controller needs to support.