Reference Guide
iDRAC.Serial.Command (Read or Write)
Description
Specifies a serial command that is executed after the user logs into the serial console interface
Legal Values
● String of up to 128 ASCII characters.
Default Value None
Write Privilege Configure iDRAC
License Required iDRAC Basic
Dependancy None
iDRAC.Serial.Enable (Read or Write)
Description
Enables or Disables the iDRAC serial console interface
Legal Values
● Disabled-0
● Enabled-1
Default Value 1
Write Privilege Configure iDRAC
License Required iDRAC Basic
Dependancy None
iDRAC.Serial.HistorySize (Read or Write)
Description
Specifies the maximum size of the serial history buffer
Legal Values
● Integral values from 0 to 8192
Default Value 8192
Write Privilege Configure iDRAC
License Required iDRAC Basic
Dependancy None
iDRAC.Serial.IdleTimeout (Read or Write)
Description
The maximum number of seconds to wait before an idle serial console session is disconnected. The special
value 0 disables the timeout.
Legal Values
● Integral values from 60 to 1920
Default Value 300
Write Privilege Configure iDRAC
License Required iDRAC Basic
Dependancy None
iDRAC Attributes 487