Reference Guide

IPMI OEM Command List | 57
GET LAN
SOURCE
OEM2 14h
Request:
Response:
Byte 1 completion code
Byte 2 Current LAN Source
00h Shared NIC
01h Dedicated NIC
GET FCB FW
VERSION
oem2 16H
Request:
Response:
Byte 1 completion code
Byte 2 FCB Fw Major number
Byte 3 FCB Fw Minor number
SET FAN
CONTROL
oem2 61H
Request:
Byte 1 Fan Control Setting
[7] Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.
Response:
Byte 1 completion code
GET FAN
CONTROL
oem2 62H
Request:
Response:
Byte 1 completion code
Byte 2 Fan Control Setting
[7] Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.