Setup Guide

Getting Started With Your System | 13
Maximum inrush current Initial In-rush Current cannot exceed
55 Amps (peak). Secondary In-rush
Current cannot exceed 35 Amps (peak).
System battery
CR 2032 3.0-V lithium ion coin cell
RAID battery (optional)
3.7-V lithium ion battery pack
Height
8.76 cm (3.45 in)
Width
44.8 cm (17.6 in)
Depth
75.1 cm (29.47 in)
Weight (maximum
configuration)
33.67 kg (74.2 lb)
Weight (empty)
15.11 kg (33.32 lb)
NOTE:
For additional information about environmental measurements for specific system
configurations, see
www.dell.com/environmental_datasheets
.
Operating 10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1°F/550 ft.
Storage 40° to 65°C (40° to 149°F) with a
maximum temperature gradation of 20°C per
hour
Operating 20% to 80% (noncondensing) with a
maximum humidity gradation of 10% per
hour
Storage
5% to 90% (noncondensing)
Operating
0.26 Grms at 5350 Hz
Storage
1.93 Grms at 10500 Hz for 15 min