Reference Guide

45
Using the Baseboard Management Controller
www
. del l . com | s u ppo rt. d e ll. c o
m
Threshold Settings and Converting Formulas
Table 1-
47
. Threshold Settings and Converting Formulas
Sensor
Number
Sensor Name The Converting Formula
Fan
Upper non
-
recoverab
l
e
Upper
cr
itical
Upper
non-
critical
Lower non-
reco
ve
rable
Lo
we
r
critical
Lo
we
r
non-critic
al
01h FCB FAN1 Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
02h FCB FAN2 Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
03h FCB FAN3 Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
04h FCB FAN4 Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
Vo
l
t
ag
e
14h PS 12V Actual_Reading (Volts) = Raw_Data x 0.062
0xD8 0xD4 0xCF 0xAB 0xAF 0xB4
15h PS 5V Actual_Reading (Volts) = Raw_Data x 0.026
0xD7 0xD3 0xCD 0xA9 0xAE 0xB3
16h STBY 3.3V Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6 0xD3 0xCD 0xA9 0xAD 0xB3
51h VCORE 1 Actual_Reading (Volts) = Raw_Data x 0.0083
0xFF 0xFF 0xFF 0x00 0x00 0x00