Error Reference Guide
POST Codes SR870BN4 Error Reference Guide
Revision 1.0
30
0xAFED OS request for SAL Clear Processor/Platform Error/State Log in progress.
South
0xAFEE SAL Platform OEM MCA Error Handler In Control.
South
0xAFEF OS request for SAL Get Processor/Platform Error/State Log in progress.
South
0xAFF0 SAL INIT Handler is in control.
South
0xAFF1 Passing Control to IA-32 OS Init Handler.
South
0xAFF2 Found valid OS_INIT Ep, Passing Control to EM OS Init Handler.
South
0xAFF3 Is a MP platform MCA condition, calling SAL_RENDZ.
South
0xAFF4 Not a MP Platform MCA Init condition.
South
0xAFF5 EM OS with no Init Handler or IA-32OS-BSP detected, Soft Rebooting.
South
0xAFF6 No OS Init Handle Registered, Checking OS Type.
South
0xAFF8 SAL PMI Handler is in Control.
South
0xAFFA OEM SAL PMI Handler is in Control.
South
0xAFFB Getting Source of PMI Event.
South
0xAFFC Power Management PMI Handler is in Control.
South
0xAFFD Platform Error PMI Handler is in Control.
South
0xAFFE Platform Flash Management PMI Handler is in Control.
South
0xAFFF Platform Emulation PMI Handler is in Control.
South
0xAF71 Recover Reliable Update - verifies the bootblock checksum and corrects if possible.
South
7.3 Recovery Port 80 Codes
Table 13. Recovery POST Codes
Code
Value
Module Display
0x8EC0 Recovery Process Started (validating CRC) South
0x8EC1 Searching for Recovery Media South
0x8EC2 Loading Recovery File South
0x8EC3 Validating Recovery File South
0x8EC4 Unlocking Flash Devices South
0x8EC5 Erasing Flash Contents South
0x8EC6 Programming Flash Contents South
0x8EC7 Validating Flash Contents South
0x8EC8 Recovery Process Complete South