Reference Guide
1-18 Dell PowerEdge Systems — Microprocessor Upgrade Guide
Figure 1-9. Removing the Cooling Shroud
Replacing the Cooling Shroud
To replace the cooling shroud, perform the following steps:
1. Hook the upper edge of the large opening on the end of the cooling shroud over
the top of the cooling fan on the system back panel.
2. Lower the other end of the shroud into place over the microprocessor(s).
3. Secure the shroud by reinstalling the two retention pins.
Installing the Upgrade Microprocessor
NOTICE: Do not attempt to operate a system with one Pentium II
microprocessor and one Pentium III microprocessor. Damage to one or both
of the microprocessors and/or the system board may occur.
NOTICE: All empty microprocessor connectors must be populated with a
terminator card. If your system supports more than one microprocessor
and you are not installing the maximum number of microprocessors, the
remaining microprocessor connectors must have a terminator card.
thumbscrew
retention pins (2)