Release Notes

Fabric OS v7.2.1e Release Notes v1.0 Page 39 of 82
Closed with Code Change in Fabric OS v7.2.1d
This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as
of November 20, 2014, in Fabric OS v7.2.1d.
Defect ID:
DEFECT000484537
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
System
Reported In Release:
FOS7.1.1
Technology Area:
Component
Symptom:
Switch CP experienced rolling kernel panic at "indirect_read_config" during blade initalization
Condition:
When a not properly seating blade or failed blade hang the PCI bus.
Recovery:
Remove the problem blade.
Defect ID:
DEFECT000487891
Technical Severity:
High
Probability:
High
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.0_pha
Technology Area:
SNMPv2, SNMPv3 & MIBs
Symptom:
Customer may encounter an FFDC from raslog KSWD-1002 "Detected termination of process
snmpd".
Condition:
SNMPd termination may be encountered most likely in embedded switches that are managed by the
FSM application when the application restarts.
Workaround:
Remove the switch from manageable list in application before restarting the application or avoid
managing switch via FSM application.
Defect ID:
DEFECT000490979
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS7.2.1
Technology Area:
FC-FC routing
Symptom:
FCR LSAN devices are stuck in initializing state
Condition:
This may occur with BR7800s shipped with FOS7.1 or later code.
Defect ID:
DEFECT000498907
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.2
Technology Area:
Web Tools
Symptom:
After resetting switch to factory default with AMM Web interface on BR5470, switch goes through a
limited cycle of rolling reboots.
Condition:
This happens when AMM Web interface is used to reset switch back to factory default.
Defect ID:
DEFECT000512347
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.1.1
Technology Area:
Access Gateway
Symptom:
Logical port WWN displayed by the "portshow" CLI may change after hot code load or haReboot on
a switch running in AG mode, followed by any subsequent offline/online event to the F_Port trunk
ports.
Condition:
This may occur under the following conditions:
- Upgrade or downgrade to firmware versions v6.1.2d, v6.2.2, or v6.3.0 and above.
- Hareboot on firmware versions v6.1.2d, v6.2.2, or v6.3.0 and above.
- Then disable / enable all ports of F-port trunk.
Workaround:
Cold boot of the switch in AG mode.