Release Notes
Fabric OS v7.2.0a Release Notes v1.0 Page 88 of 93
Closed without Code Change in Fabric OS v7.2.0
This section lists the defects with Critical, High and Medium Technical Severity closed without a code change
as of July 26, 2013 in Fabric OS v7.2.0
Defect ID:
DEFECT000412890
Technical Severity:
Critical
Summary:
Upgrade to FOS 7.0.1b may cause certain storage ports to quit passing data
Symptom:
Loss of access to storage array while performing a FOS upgrade to 7.0.1b.
Workaround:
Port persistent disable/enable on the problem port to recover.
Reason Code:
Already Fixed in Release
Probability:
Medium
Feature:
FOS Software
Function:
Firmware Download
Reported In Release:
FOS7.0.1
Service Request ID:
726935
Defect ID:
DEFECT000409665
Technical Severity:
High
Summary:
DCX PCI slot access triggered CP hang/reboot
Symptom:
DCX failed over without any reason and no panic dumps or core files were created. The failover is
followed by a EM-1051 (Inconsistency detected) for Slot 9.
Reason Code:
Can Not Fix
Probability:
Medium
Feature:
FOS Software
Function:
Panic / OOM
Reported In Release:
FOS7.0.0
Service Request ID:
750723
Defect ID:
DEFECT000423746
Technical Severity:
High
Summary:
FX8-24 comes up FAULTY(76) after inserting a non supported FC4-32 blade in another slot and
hafailover is issued.
Symptom:
FX8-24 comes up as FAULTY(76) after hafailover when an unsupported FC4-32 is also in the same
chassis.
Workaround:
Remove unsupported blade from the chassis and slotpoweroff/on the faulted blade.
Reason Code:
Can Not Fix
Probability:
Medium
Feature:
Striker/Spike Platform Services
Function:
Blade Driver
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000432407
Technical Severity:
High
Summary:
F-Port trunk comes up as E-Port (unknown) following portdisable/enable when connected to FC HBA
Brocade 1860-2 running v3.2
Symptom:
After an initial successful login, the Brocade 16G HBA running v3.2 is unable to login to a DCX
FC8-48 blade a switch portdisable/enable on the two ports. In this case, if port 10/21 (HBA port 0) is
enabled first, then it always works. If port 10/20 (HBA port 1) is enabled first, it always fails.
Workaround:
Disable both ports in the trunk. Then enable switch port connected to HBA port 0. Verify it
comes online and logs in properly. Then enable the second port and verify the same.
Reason Code:
Not Applicable
Probability:
Medium
Feature:
8G ASIC Driver
Function:
ASIC Driver
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000432662
Technical Severity:
High
Summary:
Firmware download downgrade on 8510-4 in non-VF mode is blocked with reason per user password
policies are in effect
Symptom:
While trying to downgrade from 7.1.0 to 7.0.0c on 8510-4, the system reported that per user password
policies were in place however, they did not appear to be set when showing them.
Workaround:
Reset the passwords to default and then downgrade.
Reason Code:
Not Reproducible
Probability:
Medium
Feature:
FOS Security
Function:
Other
Reported In Release:
FOS7.1.0