Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 68 of 93
Defect ID:
DEFECT000433865
Technical Severity:
High
Summary:
7800 panics when host writes data to tape drive via FCIP tunnel with fastwrite and tape pipelining
enabled
Symptom:
Write I/Os failed after a few write I/Os were completed, 7800 panics.
Workaround:
Disable FCIP Fastwrite and tape pipelining
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS7.0.1
Service Request ID:
1118991
Defect ID:
DEFECT000434032
Technical Severity:
Medium
Summary:
Remote mirroring is not working when fastwrite is enabled
Symptom:
Replication may fail when fastwrite is enabled.
Workaround:
Disable FCIP Fastwrite on the tunnel.
Risk of Fix:
Low
Probability:
Medium
Feature:
FCIP
Function:
Emulation
Reported In Release:
FOS7.0.0
Service Request ID:
1117702
Defect ID:
DEFECT000434293
Technical Severity:
High
Summary:
HTTP status queried from BNA, for Successfully completed firmwaredownload, returned as failed.
Symptom:
FirmwareDownload finished successfully in device but HTTP status returned as FAILED to BNA
Risk of Fix:
Low
Feature:
Mgmt Embedded - CAL
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000434819
Technical Severity:
Medium
Summary:
Polling container stats every 30 seconds caused free memory decrease on blade processor.
Symptom:
Continuous decrease in free memory is observed on blade processor when polling container stat every
30 seconds.
Workaround:
Reboot FS8-18 blade or BES switch
Risk of Fix:
Low
Probability:
Medium
Feature:
Data Security
Function:
Disk Encryption
Reported In Release:
FOS7.0.2
Service Request ID:
1102253
Defect ID:
DEFECT000435074
Technical Severity:
High
Summary:
FX8-24 blade DP panics with FCIP tape pipelining enabled
Symptom:
FCIP tunnels go down and become not available.
Workaround:
Disable FCIP Open Systems Tape Pipelining
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS7.0.1
Service Request ID:
1123356
Defect ID:
DEFECT000435397
Technical Severity:
Medium
Summary:
IPv6 links are not presented in Fabric Tree when connecting to switch via IPv6
Symptom:
When connecting to a switch configured with both IPv4 and IPv6 addresses from a host configured
with only IPv6, the links within the "Fabric Tree" for remote switches are presented only as IPv4.
Also, in the "Switch Information" it will not display any IPv6 information.
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
Management Embedded
Reported In Release:
FOS7.0.2
Service Request ID:
1122346