Release Notes
Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 60 of 93
Defect ID:
DEFECT000418249
Technical Severity:
High
Summary:
spinfab is failing ports when the option -nframes 0 is run on multiple switches at the same time in a
fabric.
Symptom:
Failed messages and ports seen after running spinfab -nframes 0.
Workaround:
spinfab -nframes 0 can be run in serial on mupltiple switches instead of in parallel.
Risk of Fix:
Low
Probability:
Medium
Feature:
Diagnostics
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000420473
Technical Severity:
Medium
Summary:
HTTP TRACE requests are processed over HTTPS/SSL connections
Symptom:
http trace/track methods are allowed on secure connections.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
Management Embedded
Reported In Release:
FOS7.0.0_pha
Service Request ID:
,1133738
Defect ID:
DEFECT000421461
Technical Severity:
Medium
Summary:
On DCX-4S, backend CRC errors detected on core blade port 3/56 connecting FC8-32 port blade.
Symptom:
RASLog message C2-5825 "Detect CRC error with good EOF" displayed.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
OS: Configuration
Reported In Release:
FOS6.4.2
Service Request ID:
1035401
Defect ID:
DEFECT000421839
Technical Severity:
High
Summary:
Core blades faulted due to a Port blade had HW failure
Symptom:
Rare hardware failure on port blade, caused peer core blade to fault
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS6.4.1
Service Request ID:
1092200
Defect ID:
DEFECT000421879
Technical Severity:
Medium
Summary:
When an access control list is configured for SNMP and the list contains a subnet area, that particular
subnet will not be able to query the switch
Symptom:
Not able to query SNMP from host on defined access host subnet area.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS7.0.1
Service Request ID:
1087061
Defect ID:
DEFECT000422477
Technical Severity:
High
Summary:
Unstable ICL/other ports can cause switch reboot
Symptom:
This defect has implication on DCX, FX8-24 etc., with unstable ICL/BI ports, it can cause switch to
panic.
Risk of Fix:
Low
Probability:
Medium
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS7.0.2
Service Request ID: