Fabric OS v7.2.0a Release Notes v1.0 Page 58 of 93
Closed with Code Change in Fabric OS v7.2.0
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
July 26, 2013 in Fabric OS v7.2.0
Defect ID:
DEFECT000344141
Technical Severity:
Medium
Summary:
Upon closing the Web Tools EE SID/DID performance monitoring graph, no warning message is
displayed and the EE monitor gets deleted when the EE monitor is added from Web Tools
Symptom:
No warning message is displayed upon closing the graph
Risk of Fix:
Low
Probability:
Medium
Feature:
WebMgmt
Function:
Other
Reported In Release:
FOS6.4.1
Service Request ID:
583603
Defect ID:
DEFECT000363172
Technical Severity:
High
Summary:
Call home notifications continue to use previous (old) switch name after a switch name change has
been made
Symptom:
Call home and e-mail notifications continue to use the previous (old) switch name.
Risk of Fix:
Low
Probability:
High
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS6.4.0
Service Request ID:
655745
Defect ID:
DEFECT000367396
Technical Severity:
High
Summary:
SNMP query for statistics of TX and RX of 6505 platform always returning 0
Symptom:
User will not be able to see the statistics for 6505 platform
Risk of Fix:
Low
Probability:
High
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS7.0.1
Service Request ID:
,746073
Defect ID:
DEFECT000375672
Technical Severity:
Medium
Summary:
16Gbps ISL capable ports occasionally come up at 8Gbps when cables are pulled out then plugged in
repeatedly.
Symptom:
Connecting two 16Gbps capable ports together to form an ISL may come up at 8Gbps speed.
Workaround:
Port disable/enable the affected ports
Risk of Fix:
Low
Probability:
Medium
Feature:
16G ASIC Driver
Function:
16Bbps/10Gbps Port
Reported In Release:
FOS7.0.0
Defect ID:
DEFECT000375916
Technical Severity:
Medium
Summary:
CUP Quiesce: CUP does not return Unit-check / Busy status during interval between CP failover and
firmwarecommit
Symptom:
When CUP Quiesce is operational, CUP on a dual-CP system resumes normal processing of
commands immediately after CP failover, timeouts may occur during firmwarecommit.
Risk of Fix:
Low
Probability:
High
Feature:
FICON
Function:
Ficud
Reported In Release:
FOS7.0.1