Release Notes

Open Defects in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 44 of 93
Defect ID:
DEFECT000467681
Technical Severity:
High
Summary:
Blade server shows incorrect firmware version in IOM module after a switch hotplug
Symptom:
Blade server displays incorrect Firmware Version in IOM module after switch hotplug
Feature:
Embedded Platform Services
Function:
Other
Service Request ID:
1001
Reported In Release:
FOS7.2.0
Probability:
High
Defect ID:
DEFECT000468006
Technical Severity:
High
Summary:
fmmonitor set to 4294967296 (0x100000000) after switchdisable/enable
Symptom:
fmmonitor may be set to 4294967296 (0x100000000) after switchdisable/enable instead of 0.
Workaround:
Retry the disable/enable.
Feature:
Performance Monitor
Function:
Frame Monitor
Reported In Release:
FOS7.2.0
Probability:
Low
Defect ID:
DEFECT000468007
Technical Severity:
High
Summary:
Host discovery issues in Ex on ICL ports multi chassis configuration
Symptom:
Host may not see all target LUNs in a topology using multi-chassis EX on ICL configuration
Workaround:
Portdisable enable switch ports for affected devices.
Feature:
FC Services
Function:
Name Server
Reported In Release:
FOS7.2.0
Probability:
Medium
Defect ID:
DEFECT000468188
Technical Severity:
High
Summary:
observed MDD kept crashing when a DS was set persistently disabled
Symptom:
user may see MDD hit rolling crashing when the switch is configure VF mode and the DS switch is set
disable persistently with MAPS enabled.
Feature:
Advanced Monitoring Services
Function:
Other
Reported In Release:
FOS7.2.0
Probability:
Low
Defect ID:
DEFECT000468413
Technical Severity:
High
Summary:
firmwaredownload -s on standby CP produces protocol failure in circuit setup messages on the
console
Symptom:
Firmware download on the standby CP takes a long time to reach Y/N prompt and several "poll:
protocol failure in circuit setup" console messages resulted.
Workaround:
Use firmwaredownload without the -s option.
Feature:
Striker/Spike Platform Services
Function:
VEX
Reported In Release:
FOS7.2.0
Probability:
Low
Defect ID:
DEFECT000468455
Technical Severity:
High
Summary:
QoS allowed ASIC buffer pool to become over allocated
Symptom:
Portbuffershow indicated a negative value in the remaining buffers after QoS was enabled on an
extended distance link
Workaround:
Reduce the required buffers before enabling QoS
Feature:
8G ASIC Driver
Function:
ASIC Driver
Reported In Release:
FOS7.2.0
Probability:
Medium
Defect ID:
DEFECT000468458
Technical Severity:
High
Summary:
FCR edge fabric sees NBFS messages
Symptom:
A core switch in a FCR edge fabric may see continuous NBFS event messages due to the EX-Ports
from the FCR backbone exceeding ELP retires
Feature:
8G ASIC Driver
Function:
ASIC Driver
Reported In Release:
FOS7.2.0
Probability:
Low