Release Notes

Open Defects in Fabric OS v7.2.0a
Fabric OS v7.2.0a Release Notes v1.0 Page 38 of 93
Defect ID:
DEFECT000473063
Technical Severity:
High
Summary:
Changing a FID/LS to base fabric should check for the presence of SIM ports, otherwise they get
stuck as G-ports, etc.
Symptom:
Ports that are configured as SIM ports in a FID get stuck in an invalid state, if the switch is
reconfigured to become the Base FID (an invalid state for SIM ports).
Workaround:
Easily reproducible.
No possible workaround known at this time.
The preventive step is to remove the SIM port configuration before converting a logical switch as
base switch.
“Check the SIM Port configuration before converting a Logical Switch into Base Switch. If there
are SIM Ports configured ask the user to remove the SIM Port configuration. “
Feature:
Network Patroller
Function:
ASIC interfaces
Reported In Release:
FOS7.2.0
Probability:
High
Defect ID:
DEFECT000473548
Technical Severity:
High
Summary:
When flows are monitored in MAPS, switch disable/enable or port enable/disable could trigger
unexpected MAPS RASLOGs
Symptom:
Unexpected MAPS RASLOGs with large values are triggered for the flows affected by port
enable/disable or switch enable/disable operations.
Feature:
Advanced Monitoring Services
Function:
Flows
Reported In Release:
FOS7.2.0
Probability:
High