7. Ty pe firmwareDownloadStatus to verify that the firmware has been updated.
8. Ensure that you are still logged in to the standby CP blade (the blade for which you just changed the firmware
level) and type reboot. The reboot of the standby CP will initiate a firmwarecommit to the secondary partition
and log you out.
9. Log back in to standby CP blade and type firmwaredDownloadStatus on the standby CP blade to validate a
successful commit. This may take 10 minutes.
10. Log out of the standby CP blade and log in to the active CP blade.
11. Type haEnable to reenable HA on the active CP blade.
NOTE
For FOS 6.3.0 and later, haEnable will cause the standby CP blade to reboot. Wait until the power cycles and the
POST completes before moving to the next step.
12. Type haShow and verify that the command output includes “HA Enabled Heartbeat Up”. If not, reenter the
command until you have verified that redundancy is achieved.
13. Type version or firmwareShow to verify that the firmware version has been updated.
14. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact the switch supplier to
determine the return procedure.