Reference Guide
Power over Ethernet (PoE) Commands 363
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax
CLI\files\PoE.fm
DELL CONFIDENTIAL – PRELIMINARY 10/21/13 - FOR PROOF ONLY
The following table describes the fields shown in the display:
Following is a list of port status values:
Port is on - valid capacitor detected
Port is on - valid resistor detected
Port is off - main supply voltage is high
Port is off - main supply voltage is low
Port is off -‘disable all ports’ pin is active
Port is off - non-existing port number Fewer ports are available than the
max.
Port is off - Port is yet undefined
Port is off - internal hardware fault
Port is off - user setting
Port is off - detection is in process
Port is off - non-802.3af powered device
Port is off - Overload & Underload states
Port is off – Underload state
Port is off – Overload state
Port is off - power budget exceeded
Port is off - internal hardware fault
Port is off – voltage injection into the port
Port is off - improper Capacitor Detection results
Port is off - discharged load Port fails Capacitor
Port is on – detection regardless (Force On)
Undefined error during Force On
Supply voltage higher than settings
Supply voltage lower than settings
Disable_PDU flag raised during Force On
Port is forced on, then disabled
Port is off – forced power error due to Overload
Port is off - “out of power budget” during Force On
Communication error with PoE devices after Force On
Port is off – short condition
Port is off – over temperature at the port
Port is off – device is too hot
Unknown device port status