The following table describes the system LED indications.
Hardware Components
Power Supplies
The device has an internal power supply unit (AC unit) and a connector to connect the device to an
external power supply unit (DC unit). The external unit provides redundancy and is called an RPS unit.
To power up the device, only one power supply is required. Operation with both power supply units is
regulated through load sharing.
Load sharing is where the device power requirements are divided between the two power supplies. If one
power supply has an outage, the second power supply automatically continues providing power to the
whole device.
Power supply LEDs indicate the power supply status. For more information on LEDs, see "LED
Definitions" on page 27.
Table 2-3. System LED Indications
LED Color Description
Diagnostics (DIAG) Green Flashing The system is currently running a diagnostic test.
Green Static The system passed the diagnostic test.
Red Static The system failed the diagnostic test.
Fan (FAN) Green Static The device fans are operating normally.
Red Static One or more fans are not operating.
Redundant Power Supply (RPS) Green Static The redundant power supply is currently operating.
Red Static The redundant power supply is not operating.
OFF The redundant power supply is not currently operating.
Main Power Supply (PWR) Green Static The main power supply is currently operating normally.
OFF The main power supply is not currently operating.
Red The main power supply has failed
Temperature (TEMP) OFF The system temperature is normal.
Red Static The system temperature is too high.