User guide

Configuring System Information 143
exception of the Approximated Cable Length test. The cable length returned is an approximation in the
ranges of up to 50 meters, 50m-80m, 80m-110m, 110m-120m, or more than 120m. The deviation may be
up to 20 meters.
To open the Integrated Cable Test for Copper Cables page, click System Diagnostics Integrated
Cable Test in the tree view.
Figure 6-47. Integrated Cable Test for Copper Cables
Port
— The port to which the cable is connected.
Test Result
— The cable test results. Possible values are:
No Cable
— There is no cable connected to the port.
Open Cable
— The cable is connected on only one side.
Short Cable
— A short has occurred in the cable.
OK
— The cable passed the test.
Fiber Cable
— A fiber cable is connected to the port.
Cable Fault Distance
— The distance from the port where the cable error occurred.
Last Update
— The last time the port was tested.
Approximate Cable Length
— The approximate cable length. This test can only be performed when
the port is up and operating at 1 Gbps.