Quick Reference Guide
RMON Commands 343
DELL CONFIDENTIAL – PRELIMINARY 5/15/12 – FOR PROOF ONLY
•
number
— Specifies the alarm index. (Range: 1 - 65535)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode.
User Guidelines
There are no user guidelines for this command.
Example
The following example displays RMON 1 alarms.
The following table describes the significant fields shown in the display:
Console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
Field Description
Alarm Alarm index.
OID Monitored variable OID.
Last Sample Value The statistic value during the last sampling period. For example, if the sample
type is delta, this value is the difference between the samples at the beginning
and end of the period. If the sample type is absolute, this value is the sampled
value at the end of the period.