Reference Guide

248 Power over Ethernet Commands
www.dell.com | support.dell.com
The following table describes the significant fields shown in the example:
Console> show power inline ethernet 1/e1
Port Powered Device State Priority Status Classification [w]
---- ---------------- ----- -------- ------ -----------------
1/e1 IP Phone Model A Auto High On 0.44 - 12.95
Overload Counter: 1
Short Counter: 0
Denied Counter: 0
Absent Counter: 0
Invalid Signature Counter: 0
Field Description
Power The operational status of the inline power sourcing equipment.
Nominal Power The nominal power of the inline power sourcing equipment in Watts.
Consumed Power Measured usage power in Watts.
Usage Threshold The usage threshold expressed in percents for comparing the measured
power and initiating an alarm if threshold is exceeded.
Traps Indicates if inline power traps are enabled.
Port The Ethernet port number.
Powered Device Description of the powered device type.
State Indicates if the port is enabled to provide power. Can be: Auto or
Never.
Priority The priority of the port from the point of view of inline power
management. Can be: Critical, High or Low.