Reference Guide

Line Commands 209
User Guidelines
This command is available only on the line console.
To start communication using Autobaud, press
<Enter>
twice. This configuration applies
only to the current session.
Examples
The following example enables autobaud.
exec-timeout
The exec-timeout Line Configuration mode command sets the interval that the system waits
until user input is detected. To return to the default configuration, use the no form of this
command.
Syntax
exec-timeout
minutes
[
seconds
]
no exec-timeout
minutes
— Specifies the number of minutes. (Range: 0 - 65535)
seconds
— Specifies additional time intervals in seconds. (Range: 0 - 59)
Default Configuration
The default configuration is 10 minutes.
Command Mode
Line Configuration mode
User Guidelines
To specify no timeout, enter the
exec-timeout
0 command.
Examples
The following example configures the interval that the system waits until user input is detected
to 20 minutes.
Console(config)# line console
Console(config-line)# autobaud
Console(config)# line console
Console(config-line)# exec-timeout 20