Fixed Z9100-ON 9.14(2.9) Software Issues
NOTE: Dell EMC Networking OS 9.14(2.9) includes fixes for caveats addressed in the previous 9.14 releases. Refer to the
respective release notes documentation for the list of caveats fixed in the earlier 9.14 releases.
The following caveats are fixed in Dell EMC Networking OS version 9.14(2.9):
PR# 169845
Severity: Sev 2
Synopsis: The PSU serial number displays as NA in the show inventory
command output for PSUs manufactured after January 2020.
Release Notes: The PSU serial number displays as NA in the show inventory
command output for PSUs manufactured after January 2020.
Workaround: None
PR# 169919
Severity: Sev 3
Synopsis: The switch may encounter a software exception due to invalid memory
access on bootup.
Release Notes: The switch may encounter a software exception due to invalid memory
access on bootup.
Workaround: None
PR# 169921
Severity: Sev 2
Synopsis: Static routes are not restored when BFD is disabled at interface level.
Release Notes: Static routes are not restored when BFD is disabled at interface level.
Workaround: None
PR# 169972
Severity: Sev 2
Synopsis: DHCPv6 relay-reply packet drops in the L2 VLAN when DHCPv6
relay is configured in the L3 VLAN.
Release Notes: DHCPv6 relay-reply packet drops in the L2 VLAN when DHCPv6
relay is configured in the L3 VLAN.
Workaround: None
PR# 169984
Severity: Sev 2
Synopsis: The switch may encounter a software exception when running the
show ipv6 ospf database router CLI command.
Release Notes: The switch may encounter a software exception when running the
show ipv6 ospf database router CLI command.