Release Notes
Table Of Contents
- Dell EMC Z9100–ON System Release Notes, OS Version 9.14(2.9P1)
- Document Revision History
- Requirements
- New Dell Networking OS Version 9.14(2.9) Features
- Restrictions
- Documentation Corrections
- Changes to the Default Behavior and CLI Syntax
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the sub-components
- Upgrading the ONIE Package for the Z9100-ON System
- Upgrading the DIAG Package for the Z9100-ON System
- Installing Dell EMC Networking OS on the Z9100-ON using ONIE
- Upgrading the Z9100-ON Dell EMC Networking OS Image using Dell EMC Networking OS CLI
- Uninstalling the Dell EMC Networking operating system
- Installing a Third Party Operating System
- Support Resources
Category Description
Work around
Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might
not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary,
as the version of code for which this release note is documented has resolved the caveat.
Fixed Z9100-ON 9.14(2.9P1) Software Issues
NOTE: Dell EMC Networking OS 9.14(2.9P1) includes fixes for caveats addressed in the previous 9.14 releases. Refer to the
respective release notes documentation for the list of caveats fixed in the earlier 9.14 releases.
The following caveats are fixed in Dell EMC Networking OS version 9.14(2.9P1):
PR# 169575
Severity: Sev 2
Synopsis: In certain scenarios, port configuration does not take effect and you
may see the IFMGR-3-IFA_COMM_FAIL syslog error.
Release Notes: In certain scenarios, port configuration does not take effect and you
may see the IFMGR-3-IFA_COMM_FAIL syslog error.
Workaround: None
PR# 170018
Severity: Sev 1
Synopsis: Ethernet packet type 0x888e is not handled, leading to a memory leak.
Release Notes: Ethernet packet type 0x888e is not handled, leading to a memory leak.
Workaround: None
PR# 170024
Severity: Sev 2
Synopsis: On a fully scaled switch, with all ports fanned out, some ports fail to
OPER UP after reload.
Release Notes: On a fully scaled switch, with all ports fanned out, some ports fail to
OPER UP after reload.
Workaround: None
PR# 170041
Severity: Sev 2
Synopsis: In certain scenarios, in a VLT environment, the switch may encounter
an exception during VLT failover.
Release Notes: In certain scenarios, in a VLT environment, the switch may encounter
an exception during VLT failover.
Workaround: None
6