Release Notes
Table Of Contents
- Dell EMC Z9100–ON System Release Notes, OS Version 9.14(2.9P1)
- Document Revision History
- Requirements
- New Dell Networking OS Version 9.14(2.9) Features
- Restrictions
- Documentation Corrections
- Changes to the Default Behavior and CLI Syntax
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the sub-components
- Upgrading the ONIE Package for the Z9100-ON System
- Upgrading the DIAG Package for the Z9100-ON System
- Installing Dell EMC Networking OS on the Z9100-ON using ONIE
- Upgrading the Z9100-ON Dell EMC Networking OS Image using Dell EMC Networking OS CLI
- Uninstalling the Dell EMC Networking operating system
- Installing a Third Party Operating System
- Support Resources
Z9100-ON CPLD 4 : 4
Z9100-ON MSS FPGA : 2.2
Z9100-ON MSS IAP : 2.5
Z9100-ON OOB-FPGA : 1.0
DellEMC#
NOTE: Do not power off the system while the FPGA upgrade is in progress. For any queries, contact Technical Support.
Upgrade the OOB-FPGA
To upgrade the OOB-FPGA, follow these steps:
1. Upgrade the OOB-FPGA image.
EXEC Privilege Mode
upgrade fpga-image system fpga stack-unit <stack–unit–id> booted
DellEMC#upgrade fpga-image system fpga stack-unit 1 booted
Current information for the system:
========================================================
Card Device Name Current Version New Version
--------------------------------------------------------
CP Z9100-ON OOB-FPGA 0.7 1.0
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for system 1 [yes/no]: yes
OOB FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
UNIT1 OOB FPGA upgrade successful. Power cycle the UNIT1 to complete the upgrade.
Note: Once upgrade successful,we need to power-cycle the system through software or
manually .Power cycle the system using software CLI command is as follows.
(Otherwise we need to manually remove and insert the power chords from the PSUs for
power cycle to be happened ) .
DellEMC#power-cycle stack-unit 1
Proceed with power-cycle? Confirm [yes/no]:yes
DellEMC#00:19:56: %STKUNIT1-M:CP %CHMGR-5-STACKUNIT_RESET: stack-unit 1ÿ
BIOS Boot Selector for Z9100
Primary BIOS Version 3.23.0.0-9
SMF Version: MSS 2.5, FPGA 2.2
Last POR=0x11, Reset Cause=0x44