API Guide

Table Of Contents
3. Configure the cascade ports on the C9010 which are attached to PE stack units. The cascade ports must be operationally up (the no
shutdown command) and have a default port configuration with no L2 and L3 configuration. The port interfaces must be the same
type. You can configure up to sixteen C9010 ports in the auto-LAG. The generated auto-LAG number is from 258 to 513.
PORT-EXTENDER CONFIGURATION mode
Dell(conf-pe-0)# cascade interface interface-type slot/port-range
interface interface-type specifies a C9010 10-Gigabit Ethernet interface. The only supported value is
TenGigabitEthernet slot/port-range.
slot/port-range specifies a C9010 10GbE port, including slot number and either a single port number, a port range, or a
combination of both for auto-LAG configuration.
The range of slot numbers is from 0 to 9 for linecard slots. The range of port numbers is from 0 to 23.
Enter a port range with or without spaces; for example, cascade interface tengigabitethernet 0/1-5 or cascade
interface tengigabitethernet 0/1 - 5.
You can enter up to six comma-separated ranges or port numbers; for example, cascade interface
tengigabitethernet 0/1-2,8,10–12,15.
4. Enable the C9010 cascade ports.
CONFIGURATION mode
interface tengigabitethernet slot/port-range
INTERFACE CONFIGURATION mode
no shutdown
NOTE:
Dell Networking OS recommends not to use RPM Slots 10 and 11 for PE connectivity.
Dell(conf)# feature extended-bridge
Dell(conf)# pe provision 2
Dell(conf-pe-2)# cascade interface tengigabitethernet 0/0-1
Dell(conf-pe-2)# exit
Dell(conf)# interface range tengigabitethernet 0/0-1
Dell(conf-if-range-te-0/0-1)# no shutdown
Dell(conf-if-range-te-0/0-1)# end
Dell# show pe 2
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 2
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/0(A),Te 0/1(A)
Cascade LAG: Po 258(Up)
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
Example of Dual Homed PE Stack
Dell(conf-b)#pe provision 2
Dell(conf-b-pe-2)#cascade interface TenGigabitEthernet 0/0
Dell(conf-b-pe-2)#cascade interface TenGigabitEthernet 1/4 peer
Dell(conf-b)#commit
Dell(conf-b)#end
Dell# show pe 2
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
696