Deployment Guide

Table Of Contents
270 bcmDISC 117927936 0 0 0 0 0
269 bcmATP-RX 117927936 0 0 0 0 0
268 bcmATP-TX 117927936 0 0 0 0 0
267 bcmSTACK 117927936 0 0 0 0 0
266 bcmRX 117927936 0 0 0 0 0
265 bcmLINK.0 117927936 0 0 0 0 0
!----------- output truncated --------------!
DellEMC#
show reload-type
Shows the reload type which occurs on the next reboot.
Syntax
show reload-type
Parameters N/A
Defaults normal-reload
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(0.0) Updated to include warmboot support.
8.3.11.4 Introduced on all Dell EMC Networking OS platforms.
Example
DellEMC#show reload-type
Reload-Type : warmboot [Next boot : warmboot]
Current ISSU Version 1.0
Next boot from System A
Next ISSU Version 1.0
DellEMC#
show reset-reason
Display the reason for the last system reboot.
Syntax
show reset-reason [stack-unit {stack-unit-number | all}]
Parameters
stack-unit unit-
number
(OPTIONAL) Enter the keyword stack-unit and the stack unit number to view the
reason for the last system reboot for that stack unit.
all (OPTIONAL) Enter the keyword stack-unit and the keyword all to view the
reason for the last system reboot of all stack units in the stack.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.14(0.0) Introduced on the S5048F-ON.
9.13(0.0) Introduced on the S3048ON, S3100 series, S4048ON, S4048TON, S5000,
S6000, S6000ON, S6010ON, S6100ON, Z9100ON, C9010, MXL, M-IOA, and
FN-IOM.
140 Control and Monitoring