White Papers

Table Of Contents
DellEMC(stack-member-2)#
Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt
Diags completed... Rebooting the system now!!!
The following example shows the show file flash:\\ command (standalone member).
DellEMC#show file flash://TestReport-SU-0.txt
*******************************S-Series Diagnostics***********************
Board : S4810 Dell Inc.
Stack Unit Board Serial Number : HADL112220111
CPU Version : MPC8536E, Version: 1.1
CPLD REVISION : 0x7
CPLD BOARD TYPE : 0x1
Diag image based on build : 9-4(0-89)
Stack Unit Board temperature : 50 Degree C
Stack Unit Number : 1
**************************Stack Unit EEPROM INFO**************************
**************MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id : 07
Country Code : 02
Date Code : 01222011
Serial Number : HADL112220111
Part Number : 7590009602
Product Revision : A
Product Order Number : S4810P-AC
**************************** S4810 LEVEL 0 DIAGNOSTICS**************************
diagS4810ChkPsuPresence[625]: ERROR: Psu : 0 is not present
Test 1.000 - Psu Power Good Test .................................... NOT PRESENT
Test 1.001 - Psu Power Good Test .................................... PASS
Test 1 - Psu Power Good Test ....................................... FAIL
diagS4810ChkPsuPresence[625]: ERROR: Psu : 0 is not present
Test 2.000 - Fan Psu Status test .................................... NOT PRESENT
Test 2.001 - Fan Psu Status test .................................... PASS
Test 2 - Fan Psu Status Test ....................................... FAIL
Test 3.000 - Fan board presence Test ................................ PASS
Test 3.001 - Fan board presence Test ................................ PASS
Test 3 - Fan Board Presence Test ................................... PASS
Test 4.000 - Board Fan Status Test .................................. PASS
Test 4.001 - Board Fan Status Test .................................. PASS
Test 4.002 - Board Fan Status Test .................................. PASS
Test 4.003 - Board Fan Status Test .................................. PASS
Test 4 - Board Fan Status Test ..................................... PASS
Test 5 - Fan Tray Air Flow Status Test ............................. PASS
Test 6.000 - TMP75A-CPU ............................................. PASS
Test 6.001 - TMP75B-MAC ............................................. PASS
Test 6.002 - TMP75C-LEFT-PHY ........................................ PASS
Test 6.003 - TMP75D-RIGHT-PHY ....................................... PASS
Test 6 - Temp Sensor Access Test .................................... PASS
Test 7 - RTC Presence Test .......................................... PASS
Test 8 - SDRAM Presence Test ........................................ PASS
Test 10 - Board revision Test ....................................... PASS
Test 11 - MGMT PHY Presence Test .................................... PASS
Test 12 - Board voltage Test ........................................ PASS
Trace Logs
In addition to the syslog buffer, Dell EMC Networking OS buffers trace messages which are continuously written by various Dell
EMC Networking OS software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell EMC Networking OS process. All messages are stored in a
ring buffer. You can save the messages to a file either manually or automatically after failover.
1038
Debugging and Diagnostics