Users Guide
Controlling Bridge:
==================
Minor Alarms
No minor alarms
Major Alarms
Port 2 in unit 1 high internal temperature 1 min, 33 sec
NOTE: This feature is not supported for stacking ports.
To change the optical port from reset to normal mode, you must execute the enable stack-unit unit-number port
port-number transceiver command.
Example of the show command outputs
To view if this feature is enabled or disable, use the show interface interface-name transceiver command. The
output also displays the internal temperature of the optical ports, when the physical temperature polling is enabled. If the
temperature polling is disabled, the temperature in the output is displayed as 0.
Following is an example output, when the temperature polling is enabled.
DellEMC#show interfaces tengigabitethernet 1/5 transceiver
Interface Name : TenGigabitEthernet 1/5
SFP+ is present
SFP+ 5 Serial Base ID fields
SFP+ 5 Id = 0x03
SFP+ 5 Ext Id = 0x04
SFP+ 5 Connector = 0x22
<<output truncated>>
SFP+ 5 Extended Transceiver Code = 0x01
SFP+ 5 DOM is not supported
SFP+ 5 Temperature = 55
SFP+ 5 Phy Temperature Polling = Enabled
DellEMC#
Following is an example output, when the temperature polling is disabled.
DellEMC#show interfaces tengigabitethernet 1/5 transceiver
Interface Name : TenGigabitEthernet 1/5
SFP+ is present
SFP+ 5 Serial Base ID fields
SFP+ 5 Id = 0x03
SFP+ 5 Ext Id = 0x04
<<output truncated>>
SFP+ 5 Extended Transceiver Code = 0x01
SFP+ 5 DOM is not supported
SFP+ 5 Temperature = 0
SFP+ 5 Phy Temperature Polling = Disabled
DellEMC#
To view which optical port is reset, use the show inventory media command.
DellEMC#show inventory media
Slot Port Type Media Serial Number Dell Qualified
------------------------------------------------------------------------------------
1 1 Media not present or accessible
# 1 2 SFP+ 10GBASE-T 17140074 Yes
1 3 Media not present or accessible
1 4 Media not present or accessible
1 5 Media not present or accessible
1 6 Media not present or accessible
# Transceiver is in Reset mode
The state of the optical port is seen through show interfaces interface-name command.
DellEMC#show interfaces tengigabitethernet 1/2
TenGigabitEthernet 1/2 is up, line protocol is down (error-disabled[Transceiver Reset