Release Notes
Table Of Contents
- Dell System S6000–ON 9.14(2.10) Release Notes
- Document Revision History
- Supported Hardware
- Supported Software
- New Dell Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Upgrading the CPLD
- S6000–ON Upgrade Procedures: Overview
- Upgrading the CPLD
- Uninstalling Dell Networking OS from the S6000-ON
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Support Resources
Creating new diag partition /dev/sda3 ...
Warning: The kernel is still using the old partition table.
The new table will be used at the next reboot.
The operation has completed successfully.
.
.
.
The system is going down NOW!
Sent SIGTERM to all processes
Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart
5. Upgrade the BIOS image using the BIOS image and Flashrom utility included with the diagnostic package.
ONIE:/ # flashrom -E -p internal
flashrom v0.9.10-r1711 on Linux 3.2.35-onie+ (x86_64)
flashrom is free software, get the source code at http://www.flashrom.org
Calibrating delay loop... OK.
Found chipset "Intel CentertonLPC". Enabling flash write... OK.
Found Macronix flash chip "MX25L12805(D)" (16384 kB, SPI) at physical address
0xff000000.
Erasing and writing flash chip... Erase/write done.
ONIE:/ #
ONIE:/ # flashrom -w /tmp/diag/S6000-ON-BIOS-3.20.0.3.bin -p internal
flashrom v0.9.10-r1711 on Linux 3.2.35-onie+ (x86_64)
flashrom is free software, get the source code at http://www.flashrom.org
Calibrating delay loop... OK.
Found chipset "Intel CentertonLPC". Enabling flash write... OK.
Found Macronix flash chip "MX25L12805(D)" (16384 kB, SPI) at physical address
0xff000000.
Reading old flash chip contents... done.
Erasing and writing flash chip... Erase/write done.
Verifying flash... VERIFIED.
ONIE:/ #
.
.
.
.
auto reboot
S6000–ON Upgrade Procedures: Overview
To upgrade the Dell Networking OS to the latest version, complete these steps:
NOTE:
When upgrading from an earlier version of OS9 (example: 9.10.0.1) to 9.14.2.x, first upgrade to 9.13.0.0 to prevent
any issues during the upgrade procedure.
● Upgrade the S6000–ON Dell Networking OS Image and Boot Code
● Upgrading the CPLD
● VLT Upgrade Procedure
Upgrade the S6000-ON Dell Networking OS Image and Boot Code
using Dell Networking OS CLI
Bare Metal Provisioning
NOTE:
If you are using Bare Metal Provisioning (BMP), see the Bare Metal Provisioning topic in the Dell Networking OS
Configuration Guide or the Open Automation Guide.
Manual Upgrade Procedure
6