Release Notes
Table Of Contents
- Dell System S6000–ON 9.14(2.10) Release Notes
- Document Revision History
- Supported Hardware
- Supported Software
- New Dell Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Upgrading the CPLD
- S6000–ON Upgrade Procedures: Overview
- Upgrading the CPLD
- Uninstalling Dell Networking OS from the S6000-ON
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Support Resources
EXEC Privilege Mode
show system stack-unit [1-6]
Dell#show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S6000-ON - 32-port TE/FG (SI-ON)
Current Type : S6000-ON - 32-port TE/FG (SI-ON)
Master priority : 14
Hardware Rev : 4.0
Num Ports : 128
Up Time : 1 min, 2 sec
Dell Networking OS Version : 9.14(2.10)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.20.2.5
Boot Selector : 3.20.0.3
Memory Size : 3203911680 bytes
Temperature : 33C
Voltage : ok
Serial Number : NA
Part Number : Rev
Vendor Id : DL
Date Code : 05182021
Country Code : CN
Piece Part ID : CN-08YWFG-28298-3AG-0009
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : enabled
Burned In MAC : 1a:ba:2a:b8:2d:9d
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
------------------------------------------------------------
2 1 up AC up 6720
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
----------------------------------------------------
2 1 up up 7021 up 6922
2 2 up up 6971 up 7072
2 3 up up 7021 up 6971
Speed in RPM
Dell#
Upgrading the CPLD
The S6000-ON system with Dell Networking OS Version 9.14(2.10) requires System CPLD revision 10, Master CPLD revision 12,
and Slave CPLD revision 10.
NOTE:
For the Port LEDs to work properly with the Dell Networking OS version 9.9(0.0P5), downgrade the CPLD version
to 12.
10