Setup Guide

Table Of Contents
MIB Object OID Description
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Specifies Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Specifies Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Specifies Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Specifies Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Specifies Temperature value of the Optics
inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 | grep
2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-unit-1
port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/49/1"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane2.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane3.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane4.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane1.2112517 = STRING:
"-1.433315" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane2.2112517 = STRING:
"0.051805" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane3.2112517 = STRING:
"-0.270108" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane4.2112517 = STRING:
"-0.134970" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTemperature.2112517 = STRING: "37.816406"
degrees Centigrade
MIB Support to Display the Available Memory Size
on Flash
Dell EMC Networking provides more MIB objects to display the available memory size on flash memory. The following table lists the MIB
object that contains the available memory size on flash memory.
Table 109. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object OID Description
chStackUnitFlashUsageUtil 1.3.6.1.4.1.6027.3.10.1.2.9.1.6 Contains flash memory usage in percentage.
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the flash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.
Viewing the Available Flash Memory Size
To view the available flash memory using SNMP, use the following command.
snmpget -v2c -c public 192.168.60.120 .1.3.6.1.4.1.6027.3.10.1.2.9.1.6.1
enterprises.6027.3.10.1.2.9.1.5.1 = Gauge32: 24
The output above displays that 24% of the flash memory is used.
Simple Network Management Protocol (SNMP)
801