Setup Guide

Table Of Contents
average input-power start time. These statistics can also be obtained by using the CLI command:
show environment
. The following table
lists the related MIB objects, OID and description for the same:
Table 107. MIB Objects to Display the Information for Power Monitoring
MIB Object OID Description
envMonSupplyCurrentPower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5 Displays per PSU input power (current
configuration).
envMonSupplyAveragePower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6 Displays average input power.
envMonSupplyAvgStartTime 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7 Displays average input-power start time.
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support for 25G, 40G, 50G, 100G Optical
Transceiver or DAC cable IDPROM user info
Dell EMC Networking provides MIB objects to display the information for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable
IDPROM. The following table lists the related MIB objects, OID and description for the same:
Table 108. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM user info
MIB Object OID Description
dellNetIfTransceiverData 1.3.6.1.4.1.6027.3.11.1.3 Specifies the Transceiver Data Main
dellNetIfTransceiverDataTable 1.3.6.1.4.1.6027.3.11.1.3.1 Specifies the Transceiver Data Table
dellNetIfTransceiverDataEntry 1.3.6.1.4.1.6027.3.11.1.3.1.1 Specifies the Transceiver Data Entry Point
dellNetIfTransDeviceName 1.3.6.1.4.1.6027.3.11.1.3.1.1.1 Specifies the Transceiver Device name
dellNetIfTransPort 1.3.6.1.4.1.6027.3.11.1.3.1.1.2 Specifies the Transceiver Port Name
dellNetIfTransOpticsPresent 1.3.6.1.4.1.6027.3.11.1.3.1.1.3 Specifies whether Optics is present in the
Port or not
dellNetIfTransOpticsType 1.3.6.1.4.1.6027.3.11.1.3.1.1.4 Specifies the Optic Type inserted
dellNetIfTransVendorName 1.3.6.1.4.1.6027.3.11.1.3.1.1.5 Specifies the Vendor Name of the Optic
inserted
dellNetIfTransPartNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.6 Specifies the Part Number of the Optic
inserted
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Specifies the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Specifies Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Specifies Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Specifies Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Specifies Lane 4 Tx power value in dBm
800 Simple Network Management Protocol (SNMP)