Setup Guide

Table Of Contents
OUI on 25G and 50G Interfaces
When you connect the system to another device using a 25G or 50G interface, the organizationally unique identifier (OUI) of the local
interface must match with the OUI of the peer interface for autonegotiation to work correctly.
You can set the OUI of the local interface manually using the oui command. This command is only available on 25G and 50G interfaces.
When you apply an OUI to a 25G or 50G interface, the same OUI is applied to all other fanned-out interfaces on the same physical port.
Configuring OUI on 25G and 50G Interfaces
To set the OUI on a 25G or a 50G interface, use the following commands:
To configure OUI, use the following commands.
Change the OUI of an interface:
INTERFACE mode
oui oui-value
DellEMC(Conf)# interface fiftyGigE 1/1/1
DellEMC(Conf-fi-1/1/1)# oui 0x123456
DellEMC(Conf)# interface twentyfiveGigE 1/1
DellEMC(Conf-tf-1/1)# oui 0x78abcd
Interfaces 387