Release Notes
Table Of Contents
- Dell System S6000 9.14(2.10) Release Notes
- Document Revision History
- New Dell Networking OS Version 9.14(2.10) Features
- Changes to Default Behavior and CLI Syntax
- Restrictions
- Supported Hardware
- S6000 Upgrade Procedures: Overview
- VLT Upgrade Procedure
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Support Resources
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Bootselector image upgrade for stack-unit 0 completed successfully.
6. Change the Primary Boot Parameter of the S6000 to the upgraded partition A: or B:
CONFIGURATION Mode
boot system stack-unit [0–5 | all] primary system: [A: | B: | tftp: | ftp:]
7. Save the configuration so that the configuration will be retained after a reload using write memory command.
EXEC Privilege Mode
write memory
Dell#write memory
!00:22:59: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
Dell#
8. Reload the unit.
EXEC Privilege Mode
reload
Command : reload
Mode : EXEC PRIVILEGE
Dell#reload
Proceed with reload [confirm yes/no]: y
00:23:50: %STKUNIT0-M:CP %CHMGR-5-RELOAD: User request to reload the chassis
9. Verify the S6000 has been upgraded to the Dell Networking OS version 9.14(2.10).
EXEC Privilege Mode
show version
Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9.14(2.10)
Copyright (c) 1999-2021 by Dell Inc. All Rights Reserved.
Build Time: Tue May 18 09:27:40 2021
Build Path: /build/build03/SW/SRC
Dell Networking OS uptime is 3 minute(s)
System image file is "system://A"
System Type: S6000
Control Processor: Intel Centerton with 3 Gbytes (3203911680 bytes) of memory,
core(s) 2.
16G bytes of boot flash memory.
1 32-port TE/FG (SI)
28 Ten GigabitEthernet/IEEE 802.3 interface(s)
25 Forty GigabitEthernet/IEEE 802.3 interface(s)
10. Verify that the S6000 has been upgraded to the latest Boot Flash and Boot Selector images
EXEC Privilege Mode
show system stack-unit [0-5]
Dell#show system stack-unit 0
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S6000 - 32-port TE/FG (SI)
Current Type : S6000 - 32-port TE/FG (SI)
Master priority : 0
Hardware Rev : 4.0
6