Release Notes

NOTE: If all the three fan trays are found to be empty or faulty, the system will shut down after one minute.
NOTE: The rear rack mounting bracket (SA-01-RMB-8) will fit only into racks with depths in the following ranges:
22.98 in. to 24.65 in.
27.86 in. to 30.34 in.
The following informational error message appear when a USB thumb drive is inserted or removed from the system. No action
needs to be taken when these messages appear.
Internal Messages
Dell#
Dell# umass0 at uhub3 port 1 configuration 1 interface 0
umass0: vendor 0x0930 USB Flash Memory, rev 2.00/1.10, addr 3
umass0: using SCSI over Bulk-Only
scsibus0 at umass0: 2 targets, 1 lun per target
sd0 at scsibus0 target 0 lun 0: <, USB Flash Memory, PMAP> disk removable
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0 at uhub3 port 1 configuration 1 interface 0
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0: vendor 0x0930 USB Flash Memory, rev
2.00/1.10, addr 3
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0: using SCSI over Bulk-Only
May 18 15:17:42: %S6000:0 %KERN-2-INT: scsibus0 at umass0: 2 targets, 1 lun per target
May 18 15:17:42: %S6000:0 %KERN-2-INT: sd0 at scsibus0 target 0 lun 0: <, USB Flash
Memory, PMAP> disk removable
sd0: 3850 MB, 966 cyl, 255 head, 32 sec, 512 bytes/sect x 7884800 sectors
May 18 15:17:43: %S6000:0 %KERN-2-INT: sd0: 3850 MB, 966 cyl, 255 head, 32 sec, 512
bytes/sect x 7884800 sectors
May 18 15:17:47: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk inserted in
'usbflash:'
Removal Messages
Dell#
Dell#umass0: at uhub3 port 1 (addr 3) disconnected
sd0(umass0:0:0:0): generic HBA error
sd0: detached
scsibus0: detached
umass0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: umass0: at uhub3 port 1 (addr 3) disconnected
May 18 15:17:36: %S6000:0 %KERN-2-INT: sd0(umass0:0:0:0): generic HBA error
May 18 15:17:36: %S6000:0 %KERN-2-INT: sd0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: scsibus0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: umass0: detached
May 18 15:17:37: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk removed from
'usbflash:'
S6000 Upgrade Procedures: Overview
To upgrade the Dell Networking OS to the latest version, complete these steps:
NOTE:
When upgrading from an earlier version of OS9 (example: 9.10.0.1) to 9.14.2.x, first upgrade to 9.13.0.0 to prevent
any issues during the upgrade procedure.
Upgrading the S6000 Dell Networking OS Image and Boot Code
Upgrading the CPLD
VLT Upgrade Procedure
Upgrading the S6000 Dell Networking OS Image and Boot Code
The S6000 system is pre-loaded with default Dell Networking OS software.
NOTE:
If you downgrade from Dell Networking OS version 9.14(2.10) to version 9.6(0.0) or any version prior to 9.6(0.0),
any existing quad mode configuration on the following ports is removed: 4, 12, 20, 28, 100, 108, 116, and 124
3