Release Notes
Table Of Contents
- Dell System S6000 9.14(2.10) Release Notes
- Document Revision History
- New Dell Networking OS Version 9.14(2.10) Features
- Changes to Default Behavior and CLI Syntax
- Restrictions
- Supported Hardware
- S6000 Upgrade Procedures: Overview
- VLT Upgrade Procedure
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Support Resources
NOTE: If all the three fan trays are found to be empty or faulty, the system will shut down after one minute.
NOTE: The rear rack mounting bracket (SA-01-RMB-8) will fit only into racks with depths in the following ranges:
● 22.98 in. to 24.65 in.
● 27.86 in. to 30.34 in.
The following informational error message appear when a USB thumb drive is inserted or removed from the system. No action
needs to be taken when these messages appear.
Internal Messages
Dell#
Dell# umass0 at uhub3 port 1 configuration 1 interface 0
umass0: vendor 0x0930 USB Flash Memory, rev 2.00/1.10, addr 3
umass0: using SCSI over Bulk-Only
scsibus0 at umass0: 2 targets, 1 lun per target
sd0 at scsibus0 target 0 lun 0: <, USB Flash Memory, PMAP> disk removable
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0 at uhub3 port 1 configuration 1 interface 0
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0: vendor 0x0930 USB Flash Memory, rev
2.00/1.10, addr 3
May 18 15:17:42: %S6000:0 %KERN-2-INT: umass0: using SCSI over Bulk-Only
May 18 15:17:42: %S6000:0 %KERN-2-INT: scsibus0 at umass0: 2 targets, 1 lun per target
May 18 15:17:42: %S6000:0 %KERN-2-INT: sd0 at scsibus0 target 0 lun 0: <, USB Flash
Memory, PMAP> disk removable
sd0: 3850 MB, 966 cyl, 255 head, 32 sec, 512 bytes/sect x 7884800 sectors
May 18 15:17:43: %S6000:0 %KERN-2-INT: sd0: 3850 MB, 966 cyl, 255 head, 32 sec, 512
bytes/sect x 7884800 sectors
May 18 15:17:47: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk inserted in
'usbflash:'
Removal Messages
Dell#
Dell#umass0: at uhub3 port 1 (addr 3) disconnected
sd0(umass0:0:0:0): generic HBA error
sd0: detached
scsibus0: detached
umass0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: umass0: at uhub3 port 1 (addr 3) disconnected
May 18 15:17:36: %S6000:0 %KERN-2-INT: sd0(umass0:0:0:0): generic HBA error
May 18 15:17:36: %S6000:0 %KERN-2-INT: sd0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: scsibus0: detached
May 18 15:17:36: %S6000:0 %KERN-2-INT: umass0: detached
May 18 15:17:37: %S6000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk removed from
'usbflash:'
S6000 Upgrade Procedures: Overview
To upgrade the Dell Networking OS to the latest version, complete these steps:
NOTE:
When upgrading from an earlier version of OS9 (example: 9.10.0.1) to 9.14.2.x, first upgrade to 9.13.0.0 to prevent
any issues during the upgrade procedure.
● Upgrading the S6000 Dell Networking OS Image and Boot Code
● Upgrading the CPLD
● VLT Upgrade Procedure
Upgrading the S6000 Dell Networking OS Image and Boot Code
The S6000 system is pre-loaded with default Dell Networking OS software.
NOTE:
If you downgrade from Dell Networking OS version 9.14(2.10) to version 9.6(0.0) or any version prior to 9.6(0.0),
any existing quad mode configuration on the following ports is removed: 4, 12, 20, 28, 100, 108, 116, and 124