Release Notes

......................................!
58994997 bytes successfully copied
System image upgrade completed successfully.
DellEMC#May 18 13:53:58 %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE: Upgrade completed
successfully
DellEMC#
3. Verify that the Dell EMC Networking OS has been upgraded correctly in the upgraded flash partition.
EXEC Privilege Mode
show boot system stack-unit [1-6] | all]
DellEMC#show boot system stack-unit all
Current system image information in the system:
==========================================================
Type Boot Type A B
----------------------------------------------------------
stack-unit 1 FLASH BOOT 9.14(2.10)[boot] 9.14(2.9)
stack-unit 2 is not present.
stack-unit 3 is not present.
stack-unit 4 is not present.
stack-unit 5 is not present.
stack-unit 6 is not present.
4. Change the Primary Boot Parameter of the S5048F-ON to the upgraded partition A: or B:
CONFIGURATION Mode
boot system stack-unit 1 primary system: [A: | B: | tftp: | ftp:]
5. Save the configuration so that the configuration will be retained after a reload using the write memory command.
EXEC Privilege Mode
write memory
DellEMC#write memory
!
May 18 18:58:59: %STKUNIT1-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
DellEMC#
6. Reload the unit.
EXEC Privilege Mode
reload
Command : reload
Mode : EXEC PRIVILEGE
DellEMC#reload
Proceed with reload [confirm yes/no]: y
7. Verify the S5048FON has been upgraded to the Dell EMC Networking OS version 9.14(2.10).
EXEC Privilege Mode
show version
DellEMC#show version
Dell EMC Real Time Operating System Software
Dell EMC Operating System Version: 2.0
Dell EMC Application Software Version: 9.14(2.10)
Copyright (c) 1999-2021 by Dell EMC Inc. All Rights Reserved.
Build Time: Tue May 18 08:19:32 2021
Build Path: /build/build02/SW/SRC
Dell EMC Networking OS uptime is 1 minute(s)
System image file is "system://A"
System Type: S5048F-ON
23