Release Notes

2. Upgrade the OOB-FPGA image.
EXEC Privilege Mode
upgrade fpga-image system fpga stack-unit <stackunitid> booted
DellEMC#upgrade fpga-image system fpga stack-unit 1 booted
Current information for the system:
=====================================================================
Card Device Name Current Version New Version
---------------------------------------------------------------------
CP S5048F-ON OOB-FPGA 1.0 1.0
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for system 1 [yes/no]: yes
OOB FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!
Upgrade result :
================
UNIT1 OOB FPGA upgrade successful UNIT1. Please power cycle to take effect.
To upgrade OOB-FPGA on the local region, use the upgrade fpga-image system fpga stack-unit <stack
unitid> booted command.
Upgrading the S5048F-ON Dell EMC Networking OS
Image using Dell EMC Networking OS CLI
Bare Metal Provisioning
NOTE:
If you are using Bare Metal Provisioning (BMP), see the Bare Metal Provisioning topic in the Dell EMC Networking
OS Configuration Guide or the Open Automation Guide.
Manual Upgrade Procedure
Follow these steps carefully to upgrade your S5048F-ON system:
1. Dell EMC Networking recommends that you back up your startup configuration and any important files and directories to an
external media prior to upgrading the system.
2. Upgrade the Dell EMC Networking OS in flash partition A: or B:
EXEC Privilege Mode
upgrade system [flash: | ftp: stack-unit <1-6> | tftp: | scp: | usbflash:] [A: | B:]
DellEMC#upgrade system tftp://10.16.127.6/users/pr9/FTOS-S5048F-ON-9.14.2.10.bin A:
03:18:55 : Discarded 1 pkts. Expected block num : 51. Received block num: 50
03:18:58 : Discarded 1 pkts. Expected block num : 65. Received block num: 64
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!....................
......................................!
58994997 bytes successfully copied
System image upgrade completed successfully.
DellEMC#May 18 13:53:58 %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE: Upgrade completed
successfully
DellEMC#
DellEMC#upgrade system tftp://10.16.127.6/users/pr9/FTOS-S5048F-ON-9.14.2.10.bin B:
03:18:55 : Discarded 1 pkts. Expected block num : 51. Received block num: 50
03:18:58 : Discarded 1 pkts. Expected block num : 65. Received block num: 64
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!....................
22