Release Notes
Table Of Contents
- Dell EMC S5048F–ON System Release Notes, OS Version 9.14(2.10)
- Document Revision History
- Requirements
- New Dell EMC Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the ONIE Package for the S5048F-ON System
- Upgrading the DIAG Package for the S5048F-ON System
- Installing Dell EMC Networking OS on the S5048F-ON using ONIE
- Upgrading the CPLD
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-IAP
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-FPGA
- Upgrading the OOB-FPGA
- Upgrading the S5048F-ON Dell EMC Networking OS Image using Dell EMC Networking OS CLI
- Upgrade the Boot Selector and Boot Flash Images from Dell EMC Networking OS
- Uninstalling the Dell EMC Networking OS
- Installing a Third Party Operating System
- Support Resources
stack-unit 1 S5048F-ON CPLD 3 1.0
stack-unit 1 S5048F-ON CPLD 4 1.0
stack-unit 1 S5048F-ON MSS FPGA 0.1
stack-unit 1 S5048F-ON MSS IAP 1.4
stack-unit 1 S5048F-ON OOB-FPGA 1.0
DellEMC#
Upgrading the CPLD Image
NOTE: The upgrade fpga-image system cpld stack-unit 1 booted command is hidden when using the
feature in the CLI. However, it is a supported command.
To upgrade the CPLD image, follow these steps:
1. Shut down all of the interfaces on the system.
INTERFACE Mode
shutdown
2. Upgrade the CPLD image.
EXEC Privilege Mode
upgrade fpga-image system cpld stack-unit <id> booted
DellEMC#upgrade fpga-image system cpld stack-unit 1 booted
Current information for the system:
=======================================================================
Card Device Name Current Version New Version
-----------------------------------------------------------------------
Unit1 S5048F-ON CPLD 1 1.0 1.0
Unit1 S5048F-ON CPLD 2 1.0 1.0
Unit1 S5048F-ON CPLD 3 1.0 1.0
Unit1 S5048F-ON CPLD 4 1.0 1.0
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for system 1 [yes/no]: yes
FPGA upgrade in progress!!! Please do NOT power off the
unit!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
May 18 16:16:54: %S5048F-ON:1 %DOWNLOAD-4-FPGA_UPGRADE: stack-unit 1 fpga upgrade
success.
Upgrade result :
================
Unit 1 FPGA upgrade successful Unit 1. Please power cycle to take effect.
DellEMC#
3. Power cycle the system physically. Switch off the system by unplugging the power chords from the Rear PSUs and wait until
the PSU Fan–Rear Status LED is OFF.
NOTE: Do not switch on the system with the PSU–Rear LED glowing AMBER.
You can alternatively power cycle the switch using the power-cycle stack-unit <1-6> command as follows:
DellEMC#power-cycle stack-unit 1
Proceed with power-cycle? Confirm [yes/no]:yes
4. Verify the CPLD version using the show revision command output:
18